Answered: NEC ECC: How is clause 52.1 to be applied to Covid 19 Government...

Shaun, no that is not how I think anyone intended it to work, though that doesn't necessarily mean it doesn't work that way. I am aware of some nuances around the NZ approach to C-19. Could I recommend...

View Article


NEC ECC: Time impact assessment of CEs

A Contractor in his quotation for a CE, has stated that the accepted Programme was incorrect and has "corrected" it, citing the Society of Construction Law Delay and Disruption Protocol, "“Prior to...

View Article


NEC ECC: Assessment of quotation under 61.2 request for quotation

I am facing a scenario under Option A NEC3 contract where the PM requested a quotation under clause 61.2. for additional work. The contractor submitted his quotation which the PM assessed but to a...

View Article

Answered: NEC ECC: Time impact assessment of CEs

Generally agreeing with everything Glenn says but a couple of small extra points... 1) 63.3 requires you to consider the length of time that, DUE TO A COMPENSATION EVENT, planned Completion  is later...

View Article

Answered: Are you entitled to prelim costs on additional time if you complete...

Adding to Glenn's answer... The assessment of value of a CE is not necessarily directly linked to the assessment of time. They actually serve different purposes and are calculated differently. The...

View Article


NEC ECC: Time impact assessment of CEs

A Contractor in his quotation for a CE, has stated that the accepted Programme was incorrect and has "corrected" it, citing the Society of Construction Law Delay and Disruption Protocol, "“Prior to...

View Article

Answered: NEC ECC: Assessment of CE (Time) which is as-built at Dividing Date

In October 2017 the NEC issued guidance around what they meant with their amended NEC4 clause 63.5, and then finally in 2019 version of NEC4 they have amended the wording of the contract clause 63.5 to...

View Article

Answered: NEC ECS: Would the Subcontratcor be liable for any costs for...

If there are defects in work undertaken then termination does not relieve responsibility for those defects. It does however remove the right to rectify though any cost must still be reasonable such...

View Article


Answered: NEC ECC: Sectional Completion (X5) Certificate - before or after...

Clause 30.2 provides that the PM certifies Completion within 1 weeks of Completion. The defined term "Completion" is when the work to be done by thew Completion Date has been done and notified defects...

View Article


Answered: NEC ECC: Should we notify early warnings during stage 1 ECI?

Your Client is wrong I'm afraid, Option X22 as with any other main Option or secondary Option works in conjunction with all of the core clauses, not as an alternative or as a standalone contract. With...

View Article

NEC ECC: Assessment of CE (Time) which is as-built at Dividing Date

Within NEC 4.... Cl63.5 tells us to assess the impact based on the Accepted Programme current at dividing date. Cl63.1 tells us the dividing date is the date of the communication. In most cases this...

View Article

Answered: NEC ECC: Under Clause 50.1 of the NEC3 ECC Contract does the...

I don't think so. The last sentence of clause 50.1 says:"Later assessment dates occur at the end of each assessment interval until four weeks after the Supervisor issues the Defects Certificate and...

View Article

NEC ECC Option C - Equipment rates

The Employer has just entered into a contract with a Contractor which didn't have an Equipment list included in Contract Data Part 2. The Contractor owns the majority of the Equipment to be used on the...

View Article


NEC ECC: Sectional Completion (X5) Certificate - before or after defects period?

On my contract an NEC Option A contract clause X5 is used and there are two sectional completion dates in the programme. The Contractor is almost ready to complete the works and handover. I am of the...

View Article

Answered: NEC ECC Option C - Equipment rates

Firstly, published lists for Equipment are only used in ECC Option A when the Shorter Schedule of Cost Components (SSoCC) applies, the SSoCC can only be used in ECC Option C by agreement and only then...

View Article


Answered: NEC ECC: Changes to Completion Date

By accepting a programme showing planned Completion later than it was in a previous programme the PM is not accepting any liability for an extension of time. They are merely accepting that it is a...

View Article

NEC ECC: Should we notify early warnings during stage 1 ECI?

We are working under an option C contract with X22 ECI. We are currently during stage 1, and the Client is saying we should not be raising early warnings during this stage as we are helping them with...

View Article


Answered: NEC ECC: Is the Project Manager to certify two amounts due if there...

I'm not sure the linguistic distinction you are making is particularly relevant here. There's one procedure for application, certification and payment that usually repeats on a monthly cycle. So you'll...

View Article

NEC ECC: Under Clause 50.1 of the NEC3 ECC Contract does the assessment...

Under clause 50.1 'Later assessment dates' occur at the end of each assessment interval until 4 weeks after the Defects Certificate is issued and at Completion. If Completion and the corresponding...

View Article

Answered: NEC: Subcontractor input - which is best form of contract?

If it is to provide advice and input, but not do any of the design and documents, then keep it simple: NEC4 Professional Services Short Contract (PSSC), probably on a time charge basis. Beyond that, it...